• Users Online: 342
  • Home
  • Print this page
  • Email this page
Home About us Editorial board Ahead of print Current issue Search Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2017  |  Volume : 4  |  Issue : 3  |  Page : 82-88

Comparison of retinal nerve fiber layer thickness in relation to optic nerve head size and average retinal nerve fiber layer thickness using optical coherence tomography in glaucomatous optic neuropathy


Department of Optometry, College of Health Sciences, University of Buraimi, Al Buraimi, Sultanate of Oman

Correspondence Address:
Dr. Janitha Plackal Ayyappan
P.O. Box 890, P.C. 512, Al Buraimi
Sultanate of Oman
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/bijo.bijo_11_16

Rights and Permissions

Context: This study is conducted to determine the correlation between retinal nerve fiber layer (RNFL) thickness and optic nerve head (ONH) size in normal and glaucomatous subjects by optical coherence tomography (OCT). Objective: The objective of this study is to compare the thickness of RNFL in relation to ONH size and average retinal nerve fiber thickness in glaucomatous optic neuropathy using OCT. Subjects and Methods: A prospective study was carried out on one hundred and fifty eyes of 75 patients with 39 normal and 36 glaucoma patients aged between 20 and 60 years. Results: Stratus OCT, values were correlated with the data obtained by ONHs analysis. The values of RNFL thickness showed a high correlation with the ONH size. The RNFLA values were also positively correlated with the *2.27 value. Mean RNFL in glaucoma patients is 72.20 ± 18.79 (standard deviation [SD]) and in *2.27 is 63.57 ± 17.3 (SD) (calculated Z value is 2.58 and P ≤ 0.004) and is highly significant at 4% level in glaucoma patients. Besides correlation coefficient of RNFLA*2.27 in glaucoma patients found positive correspondence with the correlation coefficient 0.867. In normal subject, mean RNFL is 92.16 ± 9.80 and in *2.27, 85.16 ± 10.21 (calculated Z value is 4.34 and P ≤ 0.007) and significant at 3% level in normal subjects. A negative correlation was seen with the value of correlation coefficient − 0.21. Conclusions: RNFL thickness *2.27 measurement has high correlation with each other as obtained by Stratus OCT; moreover, it decreased significantly with an increase in optic disc size. Statistical Analysis Used: To test the difference between two means, Z-test was used. “Z” distribution with population variance not known at that point of time because no normative-based population data were available for Indian population to find out the correlation between two variance correlation coefficient at that point of time.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed6774    
    Printed498    
    Emailed0    
    PDF Downloaded178    
    Comments [Add]    

Recommend this journal